Heavy-duty Photoelectric Sensors

PX series

Catalogues View Catalogue

Amplifier Unit, Connector Type, NPN PX-10C

PX-10C - Amplifier Unit, Connector Type, NPN

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

PX-10C

Type

Connector type

Output

NPN

Response time

500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

Output selection

LIGHT-ON/DARK-ON

Indicator lamp

- Operation indicator:Red LED x 2, DSC orange LED x 1
- Dual digital monitor:Dual 7-segment display
[Preset value (4-digit green LED) and current value (4-digit red LED) illuminated together,
current value range:0 to 65504, excess gain:0 P to 999 P]
- Hold function:Possible to display both peak and bottom hold values. Selectable from 5 variations.
- Bar LED monitor [Excess gain displayed (85% to 115% in 7 steps)]
- Scaling display

Detection mode

Light intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor]

Shift function

Variable between –1999 and 9999

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shot
Timer duration selectable:1 ms to 9999 ms
Maximum error against the setting value:10% max.

Control output

NPN open-collector 40 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max.

External input

Interference prevention

Up to 4 units (in all power modes)*1

Rating

Power voltage

12 to 24 VDC, Ripple (P-P) 10 % or less, Class 2*2

Power consumption

Standard mode:50 mA max. at 24 V/55 mA max. at 12 V
Power saving mode:40 mA max. at 24 V/45 mA max. at 12 V

Environmental resistance

Enclosure rating

IEC: IP67/JEM: IP67/NEMA: 4X

Ambient temperature

-10 to +55 °C (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Case material

Housing:PBT, display:PSU, display cover/connector cover:SUS304, radiator plate:SUS304, gasket:NBR

Weight

Approx. 50 g

*1 The received light intensity may vary somewhat when the sensor head's cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affected
somewhat when using multiple units installed adjacent to each other. Fine-tune the sensitivity (increase the setting) for adjacent layouts.
*2 Use a 24 VDC power voltage when using a head light transmitting cable of 3 m or more (PX-H71/H71TZ) or 10 m or more (PX-H72).
*3 When using multiple units connected adjacently, the ambient temperature varies with the conditions below.
2 to 4 Units: -10 to +50 °C, 5 to 17 Units: -10 to +45 °C.

Data Sheet (PDF) Other Models