Intuitive Vision System
CV-5000 series
Specs Intuitive Vision System CV-5000 series
Model |
CV-5001 |
|||
Image |
|
|||
Type |
Controller |
|||
No. of pixels |
• 512 (H) × 480 (V), Approx 240,000 pixels • 640 (H) × 480 (V), Approx 310,000 pixels |
|||
Camera input |
Two colour/monochrome |
|||
Main processor for image processing |
DSP |
|||
No. of registered settings |
SD cards 1 and 2 can each hold 1000 programs (depending on the size of the SD |
|||
Number of screens that can be registered |
Maximum 1000 screens for each program (depending on SD card size), |
|||
Internal memory capacity |
SD card slot x2 (SDHC compatible) |
|||
Window |
Measurement area |
128 locations per program |
||
Mask area |
4 locations per area |
|||
Colour extraction function (valid only when a colour camera is connected) |
Colour binary, colour shade, Gray, RGB average gray (Colours can be specified |
|||
Measurement |
Area measurement |
The shapes are rectangle, rotated rectangle, circle, oval, ring, arc or polygon (up to 12 |
||
Position detection |
Pattern search |
• Multiple searches possible for both pattern area and search area. The shapes are |
||
V-search |
• Up to 256 patterns can be searched simultaneously for both pattern area and |
|||
ShapeTrax2 |
• Multiple searches possible for both pattern area and search area. The |
|||
Edge position |
• Angles can be measured. The shapes are rectangle, rotated rectangle, |
|||
Trend edge position |
• Circle or straight line can be measured from the detection results |
|||
Blob (Centre of gravity) |
The shapes are rectangle, rotated rectangle, circle, oval, ring, arc or polygon (up |
|||
Inspection mode |
Edge position |
|||
Edge pitch |
||||
Edge count |
The shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to |
|||
Edge angle |
Shape is rectangle. |
|||
Pair edge |
The shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to |
|||
Trend edge width |
Shapes are rectangle, rotated rectangle, ring and arc |
|||
Blob (characteristic quantities) |
• Labels, center of gravity, main axis angle, area, feret diameter, perimeter, |
|||
Stain detection |
• Subtract stain detection by using subtract filter |
|||
Trend edge flaw |
• The shapes are rectangle, circle, oval, ring, arc, and polygon. |
|||
Intensity inspection |
The shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to |
|||
Colour (only when a Colour camera is connected) |
• RGB and HSB measurement supported |
|||
Geometry |
• Calculation result can be reflected |
|||
OCR |
• Character recognition for max. 2 lines of 20 characters per line |
|||
Interface |
Control input |
External trigger input |
2 points |
|
Control input |
18 inputs |
|||
Control output |
Universal output |
27 outputs NPN (including two FLASH outputs linked to external trigger.) |
||
Total comparator output |
1 output, NPN open collector, maximum 50 mA (30 V or less) |
|||
Monitor output |
SVGA 800x600 (24-bit colour 60 Hz) |
|||
Run indicator |
Power, Error LED display |
|||
RS-232C |
Numerical value output, image data (compressible) and control input/output |
|||
Ethernet |
Numerical value output, image data (compressible) and control input/output enabled. |
|||
USB |
Numerical value output, image data (compressible) and control input/output |
|||
PLC link |
Numerical value output and control input/output using the RS-232C port or |
|||
CC-Link |
By connecting the optional CC-Link unit CA-NCL10E, numerical value input/ |
|||
EtherNet/IP® |
Numerical value input/output and control input/output enabled while using an |
|||
Illumination control |
By connecting the optional illumination expansion unit, LED illumination (12 V, 24 |
|||
Continuous capture function |
• 1 to 32-time multi-measurement (maximum, minimum and average values) |
|||
Execution condition setting function |
Can set whether to execute the results (OK/NG) for other measurement and |
|||
Image |
Processing area setting function |
240,000 pixels (512 (H) x |
||
Scan mode |
Progressive/interlace selectable |
|||
Capturing start/end line setting function |
Desired capture start/end line can be set within the image capture range. |
|||
Correction |
Position adjustment |
Batch, individual (maximum 128 settings), X, Y, ±180° rotation. |
||
Camera gain adjustment |
Sensitivity adjustment, offset, and span adjustment |
|||
White balance adjustment (valid only when a colour camera is connected) |
Manual setting using white paper |
|||
Image inversion function |
Can generate mirror images |
|||
Scaling function |
X and Y calibration setting for each camera. Conversion from measurement |
|||
Filter function |
Count |
The same type of filter can be used up to 9 times. 13 steps. |
||
Type |
Expand, shrink, average, median, edge sharpening, edge extract X, edge extract |
|||
Display language |
Japanese/English/German/Italian/French/Traditional Chinese/Simplified Chinese |
|||
Calculation |
Numerical |
No. of settings |
128 calculations/1 program |
|
Arithmetic operation |
+, -, x, ÷ |
|||
Arithmetic function |
Square, exponential, counting fractions as one, round-off fractions, maximum, minimum, average, average within range, |
|||
Comparative operator |
<, ==, Not |
|||
Geometric calculation |
Distance between 2 points, angle of line segment, circle radius, circle center, |
|||
Coordinate conversion function. |
Coordinate system conversion, rotating matrix |
|||
Type conversion function |
Coordinate constant conversion, constant coordinate conversion, |
|||
Logical operator |
AND, OR, NOT, XOR |
|||
Sort function |
Maximum value index output, minimum value index output |
|||
System function |
Number of measurement times, measurement time, year, month, day, time, minute, second |
|||
Time axis operation function |
Previous measurement result acquisition operator |
|||
Command memory |
1000 command memories that can be rewritten from external devices |
|||
Support |
Statistics analysis |
No. of data |
Max. 20000 data (can be saved into an SD card in a batch) |
|
Statistical items |
Maximum, minimum, average value, deviation (3σ), total status OK/NG times |
|||
Screen save (valid when monochrome |
The following number of |
|||
Programming aid |
Image Zoom |
Between 4% and 1600% during setting or operation (6% and 2500% during full |
||
Edge derivative wave display |
Edge waveform can be graphically displayed during setting or operation, and |
|||
Profile display |
Trend edge position and gap can be graphically displayed during setting or |
|||
Stability display |
Stain detection (stain level) is displayed during setting or operation. |
|||
Cutout projection waveform display |
OCR automatic cutout waveform graphics can be displayed during setting or |
|||
Shift all windows |
Selected windows from an identical camera or an identical registered image can |
|||
Flaw level waveform |
The flaw level waveform of the trend edge tool can be displayed as a graphic in |
|||
Display template |
No. of display templates |
10 templates/1 program (within which 4 templates are specified values), |
||
No. of screens that can be displayed simultaneously |
Max. 5 screens can be displayed at the same time |
|||
Hold image |
Up to the past three images (NG images) can be displayed as hold images. |
|||
Screen customisation |
No. of customised screens |
10 screens/1 program |
||
Custom item |
Character string: Measurement value (decimal point can be specified), result, |
|||
Measurement result interlink |
• Display colour can be changed according to the result for figures and custom |
|||
Operation rewrite function |
• Upper/lower tolerance or command memory can be rewritten during operation. |
|||
Emulation function |
Built-in emulation function that can create new program data and save data on |
|||
Program file update function |
The program data used on the CV-3001 Series or CV-5001FE can be converted |
|||
Custom menu function |
Shortcut menu to a desired program screen can be created (20 menus/program). |
|||
Memory card save function (SD2 slot only) |
• Measurement value, judgment result, NG count, measurement image |
|||
Others |
Screen capture function, password function, re-test function, file management |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
2.2 A (2 cameras at maximum load) |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 1,250 g |
|||
*1 Some models also are compatible with the RS-232C, Ethernet ports in the system. |