Recent Searches
    Series ( results)
      Models ( results)
        Keywords
          Fully Operational with Expanded Resources
          Click for the latest on how KEYENCE is continuing to support our customers with quick delivery, off-site testing, virtual demos and more.
          1. Home
          2. Products
          3. Sensors
          4. Fibre Optic Sensors
          5. Digital Fibre optic Sensor
          6. Models
          7. Transmissive Fibre Unit

          Digital Fibre optic SensorFS-N40 series

          Transmissive Fibre Unit

          FU-96T

          SPECIFICATIONS

          Select Language

          Model

          FU-96T*1

          Type

          Thrubeam

          Fibre unit length

          2 m free-cut

          Fibre unit diameter

          ø2.2

          Minimum bend radius

          R25 mm*2

          Minimum detectable object

          Opaque material with a diameter of 0.2 mm*3

          Tightening torque

          0.2 N m or less

          Environmental resistance

          Enclosure rating

          IP67*4

          Ambient temperature

          0 to +60 °C (No condensation and no freezing)*5

          Relative humidity

          35 to 85 % RH (No condensation and No freezing)*6

          Material

          Main unit case : PFA, fibre sheath : PFA*4

          Accessories

          Fibre cutter

          Weight

          Approx. 35 g

          *1 For details on the detecting distance, see the fibre amplifier catalogue.
          *2 The section 25 mm in length from the screw cap tip of the main unit case cannot be bent.
          *3 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.
          *4 Using this product in high-temperature liquids or steam may lead to penetration of the fluorocarbon polymers, which may cause fluctuations in the received light intensity and damage to the internal components.
          *5 Use this product under the condition that if the ambient temperature exceeds 60 °C, the absolute humidity is 60 °C 85%RH or less.
          *6 Use this product under the condition that if the ambient temperature exceeds 60 °C, the absolute humidity is 60 °C 85 % RH or less.