SPECIFICATIONS

Select Language

Model

FS-T0

Type

0-line expansion unit

Output

-

Light source

Red LED

Sensitivity adjustment/Mode selection

Button

Response time

410 µs to 1 ms*1

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output indicator: Red LED, Stable operation indicator: Green LED Calibration indicator: Orange LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

Input

Non-voltage input (contact, solid state)

Control output

Stability output

Protection circuit

Reversed polarity protection, Overcurrent protection, Surge absorber

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units)*2

Mutual interference suppression

FINE : 4, TURBO/SUPER: 8

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*3

Current consumption

35 mA or less

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-10 to +55 °C (No freezing)*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Weight

Approx. 20 g

*1 The response speed varies depending on the number of expansion units connected.
*2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F)
*3 Power to the FS-T2/T0/M2/M0 is supplied through the FS-T1/M1/V1/V11/R0, PS-T1, LV-21A/11A or CZ-V1.