Built-in amplifier photoelectric sensors

PZ2 series

Catalogues View Catalogue

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Recommended Replaceable Products: Square Transmissive Cable Type, PNP - PZ-G51P

Square Transmissive Cable Type, PNP PZ2-51P

PZ2-51P - Square Transmissive Cable Type, PNP

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Specifications

Model

PZ2-51P

Type

Thrubeam

Detection distance

7 m

Light source

Red LED

Detectable object

30 mm2 dia. min. opaque materials

Hysteresis(of detecting distance)

-

Sensitivity adjustment

1-turn trimmer (240°)

Response time

1.5 ms max.

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output and power*1: Red LED, Stable operation: Green LED

Controloutput

NPN or PNP: 100 mA (40 V) max., Residual voltage: 1 V max.

Protection circuit

Reversed polarity, overcurrent protection, surge absorber

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

Transmitter: 20 mA or less, Receiver: 25 mA or less

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-20 to +55 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Case material

Glass-fibre reinforced plastic

Accessories

Mounting bracket x 2, Mounting screws x 4, Plate nut x 2

Weight

Approx. 50 g (including 2-m connector cable)

*1 The power indicator is equipped with the PZ2-51 only.