High-Performance Micro Static Eliminator

SJ-M series

Catalogues View Catalogue

Spot Type Main Unit, Head Cable 2-m and CAB Needle SJ-M021G

SJ-M021G - Spot Type Main Unit, Head Cable 2-m and CAB Needle

  • CE Marking
  • CSA

Specifications

Model

SJ-M021G

Type

Static Elimination Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec. max.*1

Ion balance

±15 V or less*2

Air purge supplied pressure

0.001 to 0.5 MPa*3

Min. air pressure

With SJ-ML

0.02 MPa (20 Nl/min)

With SJ-MS/ML1

0.03 MPa (20 Nl/min)

With SJ-MS/ML2

0.02 MPa (20 Nl/min)

With SJ-MS/ML3

0.08 MPa (50 Nl/min)

With SJ-MS/ML4

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open collector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10 %

Current consumption

450 mA or less

Environmental resistance

Ambient temperature

0 to +80 °C*4*5

Relative humidity

35 to 65 % RH

Weight

Approx. 600 g

*1 Values obtained at an installation distance of 50 mm and air flow rate of 60 Nl/min [ambient operating temperature +20 to +30 °C, ambient operating humidity 40 to 60 % RH] (without nozzle)
*2 Values obtained at an installation distance of 50 mm and air flow rate of 20 Nl/min [ambient operating temperature +20 to +30 °C, ambient operating humidity 40 to 60 % RH] (without nozzle)
*3 Inquire for derating of humidity/pressure in environments exceeding +35 °C. Use clean or dry air at a temperature of -20 °C or less. Min. air pressure varies by nozzle used.
*4 Use a supplied fluid with a temperature of 40 °C or less.
*5 Only for the pressure cable. Other parts should be used with an ambient temperature of 0 to 40 °C.